Source 0.22 micron PES, PTFE, Nylon, and suitable membrane-filter cartridge options for pharmaceutical, biotech, chemical, food, beverage, laboratory, and high-purity process-filtration applications.
ScientificEdge helps laboratories structure product, grade and documentation requirements for instruments, chemicals, filtration systems and consumables before supply is confirmed.
Authentic Supply
Product identity and requested make reviewed against the exact sourcing requirement.
Documentation Support
Clear technical specs, compliance details, and buying clarity.
PAN-India Delivery
Timely fulfilment with responsive coordination across regions.
Partner Confidence
Brand-focused sourcing support
For pharma, research, diagnostics and industrial laboratories that need clear product and documentation discussions.
Featured Brand Portfolio
30 local brand logos
ScientificEdge supports sourcing and supply of suitable 0.22 micron cartridge filters, membrane filter cartridges, critical-filtration options, vent filters, and pre-filters based on membrane material, application, process fluid or gas, flow rate, pressure, end-cap configuration, validation requirement, documentation, and buyer specification.
A 0.22 micron cartridge filter is a pleated membrane element used for fine particulate reduction and for critical-filtration workflows where a very tight rating is required. Some product models are validated by their manufacturer for sterilizing-grade use — but the 0.22 micron rating on its own does not confirm that a filter is suitable for a specific sterile or regulated application. That determination comes from the product's own documentation and your validation strategy, not from the number.
Because the rating is settled the moment you land on this page, the membrane material becomes the whole decision. It governs chemical compatibility, whether the membrane wets with liquid or repels it, how much flow you get for a given pressure drop, protein and analyte binding, extractables behaviour and which sterilization regimes the construction tolerates. Two cartridges both marked 0.22 micron in PES and in hydrophobic PTFE are not alternatives to each other; they are built for opposite duties.
Final selection must follow the exact manufacturer datasheet, the actual process fluid or gas, your validation strategy and your QA requirements. Retention behaviour, flow and pressure-drop curves, operating and sterilization limits, integrity-test method and values, and materials of construction throughout the cartridge all vary by product model, and none of them follows from the pore rating.
One practical point decides how long the filter lasts and how much it costs to run. A 0.22 micron membrane is the finest and most expensive element in most trains, and it blinds quickly if it is asked to carry bulk particulate. Where the load is anything but light, it belongs behind appropriate pre-filtration — a depth or spun element for gross solids, often with a coarser membrane or pleated stage between. Specifying the final filter without the stage in front of it is the commonest reason a 0.22 cartridge is replaced far sooner than it should be.

Rating ≠ sterility
What 0.22 micron does not tell you
Sterilizing-grade is a designation a manufacturer earns for a specific product by bacterial challenge under stated conditions. The pore rating alone is not that claim.
5 materials
PES, PTFE ×2, Nylon, pleated media
With the rating fixed, the membrane is the entire selection. Compatibility, wetting behaviour, flow and binding all follow from it.
Pre-filter first
What keeps the cost per litre sane
The finest element in the train is the wrong place to catch bulk solids. Sizing the stage ahead of it usually costs less than replacing the membrane more often.
The rating is already decided. Everything that distinguishes one 0.22 micron cartridge from another is in this table.
| Membrane material | Commonly selected for | What to confirm |
|---|---|---|
| PES — polyethersulfone | Suitable aqueous, pharmaceutical, biotech and process-liquid applications where the selected product documentation supports the intended use | Naturally hydrophilic, so it wets with water without a pre-wetting step, and it is generally specified where throughput on aqueous fluids matters. Confirm protein-binding behaviour where the product itself is the thing being filtered, and confirm compatibility before use with solvents |
| Hydrophobic PTFE | Suitable air, gas, moisture-resistant venting and selected solvent applications | Repels water, so a vent keeps passing gas in humid service where a wettable membrane would block. It will not pass aqueous liquid without being forced. On vent duty, size the element on the fastest rate liquid enters or leaves the vessel rather than on the vessel's volume |
| Hydrophilic PTFE | Suitable aggressive chemical, acid, alkali, solvent and liquid-filtration applications where compatibility is confirmed | Surface-modified to wet out and pass liquid while retaining PTFE's chemical-resistance characteristics. Confirm compatibility against the whole cartridge — supports, cage, core, end caps and seals are usually not PTFE and commonly reach their limit first |
| Nylon | Selected aqueous and solvent filtration applications, subject to sample compatibility and extractables requirements | Broadly compatible across aqueous and many organic fluids and naturally wettable. It can bind some proteins and analytes, so on product-contact and trace-analysis duty confirm binding and extractables behaviour for the specific product rather than assuming it from the material |
| Other pleated media | Selected particulate-reduction and pre-filtration duties, depending on product design | Pleated polypropylene, glass fibre and similar constructions rated at or near 0.22 micron, generally specified to protect a membrane stage or for clarification rather than for critical retention. Confirm how the rating is defined for the specific product, since these are often nominal rather than absolute |
Always verify chemical compatibility, filter integrity requirements, sterilization conditions, and intended use before ordering. Retention behaviour, flow and pressure drop, operating and sterilization limits, integrity-test method and values, and materials of construction throughout the cartridge are confirmed against the documentation for the specific item quoted rather than assumed from the pore rating or the membrane name.
This is the single most consequential misunderstanding on this product, and it is worth being blunt about. Sterilizing-grade is not a property of a pore size. It is a designation a manufacturer earns for a specific product, by challenging that filter with bacteria — conventionally Brevundimonas diminuta at a defined loading per unit of filter area, by the method described in ASTM F838 — and demonstrating sterile effluent under stated conditions of fluid, flow, pressure and time. A cartridge that has not been through that programme is a 0.22 micron filter. It is not a sterilizing filter, whatever the label says.
The rating itself is also less absolute than it looks. There is no instrument that measures a membrane and returns "0.22"; the number is a designation the manufacturer applies, correlated to its own retention testing. That is why you will see 0.2 µm and 0.22 µm used by different makers for products in the same class, and why two cartridges both marked 0.22 micron cannot be treated as interchangeable on the strength of the number. Retention at this scale is not pure sieving either — adsorptive capture contributes, and it varies with the fluid, the differential pressure and how long the filtration runs, which is precisely why validation is done on the process rather than inferred from the specification.
Integrity testing is what connects the installed filter back to that work. A bubble point, diffusion or pressure-hold measurement is correlated by the manufacturer to the retention testing performed on that product, so passing it confirms the membrane and its seals are intact and match the condition the data applies to. The values are product-specific and must come from that item's own guide. Note too that a hydrophobic filter is not tested the same way a wetted hydrophilic one is. And an integrity test tells you the filter is sound; it does not by itself establish that your process is validated.
What this means in practice is straightforward. If the duty is genuinely sterilizing — final filtration of a product, injectable or WFI-related use, aseptic processing — the requirement is a named product with a validation guide, a documented integrity-test method and limits, and your own QA's approval of the change. If the duty is fine particulate reduction, clarification or protecting a downstream stage, a 0.22 micron cartridge is often exactly right and none of that apparatus is needed. Tell us which of the two you are doing, because it changes the answer completely and it is the thing most enquiries leave out.
End-cap code, seal material and housing compatibility have to be confirmed before a quotation — a correctly specified membrane in the wrong end-cap code will not seat.
The standard length range for single and multi-round sanitary and industrial housings.
Positive bayonet retention with a double O-ring seal, where bypass around the element cannot be tolerated.
Double O-ring seal with a flat end, used where the housing is built for it — the codes are not interchangeable.
Compression-sealed between plates, simpler and less expensive where the duty tolerates it.
Self-contained disposable formats with integral housing, common for small-batch, pilot and laboratory work.
Tank-vent and gas duty, sized on the vessel's fastest transfer rate rather than on its volume.
PES, hydrophilic PTFE and Nylon elements for aqueous, solvent and aggressive-chemistry liquid duty.
Stainless housings with tri-clamp connections, drain and vent arrangements and test connections.
O-ring and gasket materials selected against the fluid, temperature and sterilization regime.
The stage that decides how long the membrane lasts — spun, pleated and coarser membrane elements ahead of the final filter.
Sourcing support for test connections, vent and drain arrangements and instrumentation, where required.
The same rating turns up in very different duties. Which one you are in decides whether a validation file is part of the specification or not.
Solution, buffer and intermediate filtration steps, with the required documentation set by how the step is classified in your validation strategy rather than by the rating.
Buffers, media and biological solutions, where membrane binding matters as much as retention because the product itself passes through the filter.
Hydrophobic PTFE elements on vessel vents, fermenter air and compressed-gas lines, sized on transfer rate and kept dry in condensing service.
Hydrophilic PTFE and Nylon where the chemistry would attack other membranes, with compatibility confirmed across the whole cartridge construction.
Clarification and final polishing on product streams, plus CO₂ and tank-vent gas filtration, with material documentation confirmed per product.
Point-of-use polishing downstream of RO, EDI or polishing resin, where the filter protects the distribution loop rather than performing a sterilizing step.
Aggressive process chemistry where cleanliness and extractables matter alongside particulate control and chemical resistance.
Capsule and mini-cartridge formats for development work, chosen so the specification scales to production later rather than being re-selected then.
These are the duties a 0.22 micron cartridge commonly appears in. Injectable final filtration, WFI-related use, sterile drug manufacturing, aseptic processing and defined microbial-retention requirements are not covered by a pore rating: they require a product validated for that use, an integrity-test regime, and process approval by the buyer's QA and validation function.
Thirteen inputs turn a pore rating into a specific recommendation. The first two are the ones that actually select the product.
Process fluid or gas — and whether the duty is critical or particulate reduction
Required membrane chemistry, or the application it has to suit
Required pore size, where a different rating may serve better
Flow rate and allowable differential pressure
Cartridge length and the housing configuration it must fit
End-cap style and seal or O-ring material requirement
Operating temperature and pressure
Sterilization, SIP or autoclave requirement, if applicable
Integrity-test method or validation-document requirement, if any
Pre-filtration already in place, or whether the stage still needs specifying
Preferred brand and model, or the approved-vendor list your QA has qualified
Quantity and how often the element is expected to be replaced
Delivery city and project timeline
For applications requiring sterilizing-grade filtration, integrity testing, steam sterilization, compatibility data, or validation documentation, ScientificEdge can support product-selection and document enquiries based on the manufacturer's product guide, intended use, process conditions, and buyer QA requirements.
Pore rating and how it is defined, materials of construction throughout, flow and pressure-drop data and operating limits for the specific item.
Where the manufacturer issues one — the basis of any sterilizing-grade designation, the conditions it applies under, and its supporting data.
The test method appropriate to that product and membrane, with its values and conditions. Hydrophobic and hydrophilic elements are not tested the same way.
Compatibility across the whole cartridge — membrane, support, cage, core, end caps and seals — against your fluid at its concentration and temperature.
Extractables data and biological-safety information, where the manufacturer produces them for that product.
COA or batch-related documentation, where it is issued for the item and lot supplied.
These documents are not available for every product or every brand, and their scope differs considerably. Sterilizing-grade designation, integrity-test values, sterilization cycle limits, extractables data, biological-safety information and any USP or compendial reference are claims a specific manufacturer makes for a specific product under stated conditions; ScientificEdge coordinates and supplies that documentation where it exists and does not itself validate, test, certify or confer any of it. A 0.22 micron pore rating is not by itself evidence of sterilizing-grade performance, integrity testing, steam or SIP compatibility, extractables profile, or suitability for injectable or WFI-related use. Determining that a filter is suitable for your fluid and your process — including any validation a regulated process requires — remains the responsibility of the buyer's QA, validation, process or engineering function.
Two things are worth stating in writing at enquiry, because they change what gets quoted. First, whether the step is a validated critical duty or particulate reduction — the same cartridge may serve both, but only one of them needs a documentation package. Second, what sits upstream: a 0.22 micron element asked to carry bulk solids will be replaced far more often than the specification suggests, and pre-filtration is usually the cheaper half of the answer.
ScientificEdge supports sourcing enquiries for 0.22 micron membrane filter cartridges, capsule filters, vent filters, sanitary housings, and related filtration products from suitable reputed brands and suppliers, including Sartorius, Pall, Merck Millipore, Parker domnick hunter, Cobetter, Graver, and equivalent options, subject to availability, technical compatibility, documentation, and buyer requirement.
Brand names indicate the sourcing enquiries ScientificEdge can support. They do not indicate authorised distribution, official dealership or an exclusive partnership, and no brand logos or compliance badges are displayed. Product and series names are the trademarks of their respective owners and are referenced only because buyers and tender documents specify by them. An equivalent is matched on membrane material, pore rating and how that rating is defined, full materials of construction, dimensions, end-cap code and seal material — and where the step is a validated one, substituting a filter is a change to a qualified arrangement, so equivalence is your QA or validation function's determination rather than ours.
Most enquiries for this product arrive as a rating and a quantity. Establishing what the filter is actually doing is usually the first useful thing that happens.
A supply partner in India for pharmaceutical, biotech, chemical, food and beverage and high-purity process teams.
Help choosing between PES, hydrophobic and hydrophilic PTFE, Nylon and pleated media once the rating is settled.
Datasheets, validation guides, integrity-test guidance and compatibility information where the manufacturer issues them.
From a single capsule for development through qualified recurring supply for production.
The stages around the membrane, including the pre-filtration that decides how long it lasts.
A clear line between fine particulate duty and validated critical duty, so the quotation matches the requirement.
Commercial paperwork in the form your procurement requires, with dispatch coordination from Delhi NCR across India.
Fields marked with an asterisk are required. The application and membrane material select the product; the flow, housing and sterilization details decide whether it will work in your installation.
A pleated membrane element rated at 0.22 micron, built into a standard cartridge envelope with end caps that seat into a matching housing. It is used for fine particulate reduction and for critical-filtration workflows where a very tight rating is required, and it is supplied in several membrane materials — PES, hydrophobic and hydrophilic PTFE, Nylon and other pleated media.
The rating describes how the manufacturer designates that membrane, correlated to its own retention testing. It is not a measured universal aperture, and it does not by itself describe what the filter is qualified to do. Two cartridges both marked 0.22 micron in different materials are built for different duties and are not interchangeable.
No. Sterilizing-grade is a designation a manufacturer earns for a specific product by challenging that filter with bacteria — conventionally Brevundimonas diminuta at a defined loading per unit of filter area, by the method described in ASTM F838 — and demonstrating sterile effluent under stated conditions of fluid, flow, pressure and time.
A cartridge that has not been through that programme is a 0.22 micron filter and nothing more. Where a sterilizing duty is genuinely required, the specification is a named product with a validation guide, a documented integrity-test method and limits, and approval by your QA and validation function. Where the duty is particulate reduction or clarification, a 0.22 micron cartridge is often exactly right and none of that is needed.
The membrane material, and therefore what each is built to do. PES is naturally hydrophilic and is commonly specified for aqueous, pharmaceutical and biotech liquid duty where throughput matters. Hydrophobic PTFE repels water and is used for air, gas and tank-vent duty. Hydrophilic PTFE is surface-modified to pass liquid while keeping PTFE's chemical resistance, so it suits solvents, acids and alkalis. Nylon is broadly compatible across aqueous and many organic fluids and is naturally wettable.
Beyond compatibility, the material governs wetting behaviour, flow for a given pressure drop, protein and analyte binding and extractables behaviour. Because the rating is the same across all of them, the material is effectively the whole selection — and confirming compatibility against the full cartridge construction matters, since supports, cage, core, end caps and seals are frequently a different polymer from the membrane.
Hydrophobic PTFE, because a vent has to keep passing gas in service that is often humid or condensing, and a wettable membrane would block as soon as condensate reached it.
Sizing matters more than on most cartridges. A vent must pass gas at least as fast as liquid leaves the vessel, or the tank goes into vacuum — and tanks are considerably weaker in vacuum than in pressure. Size on the fastest transfer rate the vessel will see plus any steam or CIP flow, not on tank volume. In condensing service a heated or jacketed housing keeps the membrane dry, and the element should be dried after steam sterilisation before the vessel returns to transfer duty.
Usually hydrophilic PTFE, and in some duties Nylon, where the selected product is designed and documented for that fluid. Hydrophilic PTFE wets with liquid while retaining the chemical resistance that made PTFE the choice, which is what suits it to solvents, acids, alkalis and reagents.
Confirm compatibility against the whole cartridge rather than the membrane alone. Support layers, cage, core, end caps and O-rings are usually polypropylene or another polymer, and on aggressive chemistry those commonly reach their limit before the membrane does — the seal material in particular is frequently the weakest component and the easiest to specify wrongly. Where the fluid is the product and trace contamination matters, ask for extractables information as well as a compatibility chart.
They describe how the cartridge seals into the housing. DOE — double open end — is a plain element sealed by compression between plates. Code 7 has a 226 O-ring at one end with a bayonet lock and a fin or spear at the other, positively locating the element so it cannot lift or bypass under flow or a pressure surge. Code 3 uses a 222 O-ring with a flat end.
The codes are not interchangeable, and a Code 7 element will not seat in a Code 3 or DOE housing. Where a defined retention is the point, positive O-ring retention is normally specified, because a compression seal that relaxes leaves a bypass path around the membrane and the rating then means nothing. Confirm the code, and the seal material, against the housing before ordering.
A non-destructive measurement on the installed filter, correlated by the manufacturer to the retention testing performed on that product, confirming the membrane and its seals are intact and that the assembly matches the condition the data applies to.
A wetted hydrophilic filter is generally tested by bubble point, diffusion or pressure hold. A hydrophobic filter cannot be water-wetted the same way, so hydrophobic elements are commonly tested by a water intrusion method or an alcohol-based wetting procedure, depending on the product. Both the method and its limits are product-specific and must come from that item's own guide rather than from a general figure. An integrity test confirms the filter is sound; it does not by itself establish that your process is validated.
Datasheets, validation guides, integrity-test guidance, chemical compatibility information, extractables or biological-safety documentation and Certificates of Analysis can be coordinated where the relevant manufacturer issues them for the specific product.
They are not available for every product or brand, and their scope differs considerably. State what your file needs at enquiry — particularly whether a validation guide is required, since that narrows the product list immediately — and availability can be confirmed for the specific item before an order is placed. ScientificEdge supplies this documentation where it exists and does not itself validate, test or certify any of it.
Sourcing enquiries are supported for reputed brands including Sartorius, Pall, Merck Millipore, Parker domnick hunter, Cobetter and Graver, along with equivalent options, subject to availability, technical compatibility, documentation and buyer requirement.
This does not indicate authorised distribution, official dealership or an exclusive partnership with any brand. An equivalent is matched on membrane material, pore rating and how that rating is defined, full materials of construction, dimensions, end-cap code and seal material. Where the step is a validated one, substituting a filter is a change to a qualified arrangement, so whether an equivalent is acceptable is your QA or validation function's determination rather than a sourcing question.
Yes. Supply and project coordination run from Delhi NCR across Gujarat, Maharashtra, Tamil Nadu, Telangana, Karnataka, West Bengal and other industrial and pharmaceutical clusters, covering production, pilot, laboratory and institutional requirements.
Cartridges are supplied individually packaged and should be stored sealed, clean and dry within the temperature range the manufacturer states. Lead time is confirmed per line item at quotation stage; commonly held materials and lengths move quickly, while specific brands, capsule formats and documented product lines are often imported to order — worth allowing for if the element is on a qualified list.
The material pages behind this rating, the stages that protect a membrane, and the systems it usually sits downstream of.
Connect with ScientificEdge for dependable product selection, transparent quotations, and quick support across laboratory equipment, chemicals, filtration, and ultrapure water workflows.
Why Teams Choose Us
Certified Product Range
Equipment, chemicals, filtration, and water systems from trusted brands.
Technical Buying Support
Practical recommendations based on workflow, compliance, and budget.
Fast PAN-India Dispatch
Coordinated fulfilment with clear updates and responsive communication.