Authentic Supply
Product identity and requested make reviewed against the exact sourcing requirement.
Source hydrophobic PTFE vent filters, hydrophilic PTFE chemical and solvent filters, 0.22 micron filtration options, capsule filters, sanitary housings and related process-filtration products for pharmaceutical, biotech, food, chemical and industrial applications.
ScientificEdge helps laboratories structure product, grade and documentation requirements for instruments, chemicals, filtration systems and consumables before supply is confirmed.
Authentic Supply
Product identity and requested make reviewed against the exact sourcing requirement.
Documentation Support
Clear technical specs, compliance details, and buying clarity.
PAN-India Delivery
Timely fulfilment with responsive coordination across regions.
Partner Confidence
Brand-focused sourcing support
For pharma, research, diagnostics and industrial laboratories that need clear product and documentation discussions.
Featured Brand Portfolio
30 local brand logos
ScientificEdge supports sourcing and supply of suitable hydrophobic and hydrophilic PTFE membrane filter cartridges, tank-vent filters, compressed-gas filters, solvent and chemical filtration cartridges, capsule filters, and sanitary housings based on pore size, process fluid or gas, chemical compatibility, flow rate, end-cap configuration, operating pressure, sterilization conditions, documentation, and buyer requirement.
PTFE is a fluoropolymer membrane material selected largely for its chemical-resistance characteristics, and it is unusual in being supplied in two forms that do opposite jobs. Hydrophobic PTFE repels water and is commonly used for gas, air and tank-vent duty. Hydrophilic PTFE is surface-modified so it wets with liquid, and is used for aqueous, solvent and chemical filtration.
Getting that fork right is the first decision on this page and the one most often reversed in practice. A hydrophobic element put into liquid duty will not pass liquid until it is forced to, and a hydrophilic element put on a vent loses its water-repellent behaviour and will block when condensate reaches it. They look similar in a housing and behave completely differently, so the form is specified before anything else.
The reason PTFE is reached for at all is chemical resistance — acids, alkalis, solvents and aggressive process chemistry that would attack other membrane materials. That property belongs to the membrane, and it is worth saying plainly that a cartridge is not made only of membrane. Support layers, the cage, the core, the end caps and the O-rings are usually polypropylene or another polymer, and in most cases those set the real compatibility and temperature envelope rather than the PTFE does.
Final cartridge selection must be based on the actual process fluid or gas, its concentration, the operating temperature and pressure, the filtration target, and the manufacturer's documentation for the specific product. Pore ratings and how they are defined, retention behaviour, gas and liquid flow, pressure drop and sterilization limits all vary by product model — none of them follows from the material name.

Two forms
Hydrophobic and hydrophilic
One repels water for gas and vent duty; the other is surface-modified to wet for liquid duty. Specifying the wrong one is the most common error on this product.
Membrane ≠ cartridge
Where compatibility is actually set
Support, cage, core, end caps and O-rings are usually not PTFE, and generally limit the chemical and temperature envelope before the membrane does.
Fails closed
What a wetted vent filter does
A blinded tank vent restricts or stops flow, which on a tank being emptied means vacuum. Vent sizing and drying are safety matters, not housekeeping.
Two forms of the same polymer, doing opposite jobs. This choice comes before pore size, length or brand.
| PTFE form | Commonly selected for | What to know |
|---|---|---|
| Hydrophobic PTFE | Suitable gas, air, compressed-gas, tank-vent and moisture-resistant vent-filter applications | Repels water, so a vent keeps passing gas in humid service where a wettable membrane would block. It will not pass aqueous liquid without being forced, which is the property being bought — and also the reason a wetted hydrophobic vent restricts flow until it is dried |
| Hydrophilic PTFE | Suitable aqueous, solvent, acid, alkali and chemical-liquid filtration where the selected product is designed and documented for that fluid | Surface-modified to wet out and pass liquid while retaining PTFE's chemical-resistance characteristics, which is why it is reached for on solvent and aggressive-chemistry duty rather than a standard hydrophilic membrane |
Always confirm compatibility with the exact chemical, concentration, temperature, pressure and process conditions before ordering — and confirm it against the full cartridge construction rather than the membrane alone, since supports, cage, end caps and seals are generally not PTFE.
Four bands across the PTFE range. As with the form, the rating follows the filtration objective rather than the finest option available.
| Pore size band | Typical use | What to confirm |
|---|---|---|
| 0.1 micron and finer options | Specialised fine-filtration applications | Used where the selected product documentation supports the requirement. Flow falls sharply at these ratings on both gas and liquid duty, so the pressure drop across the intended flow is worth checking before the size is fixed |
| 0.22 micron options | Suitable gas, vent, liquid or sterilizing-filtration workflows | Specified where the exact product is validated for the intended use. Any sterilizing-grade designation, its integrity-test method and the conditions it applies under come from that product's own documentation |
| 0.45 micron options | Pre-filtration, particulate reduction and clarification workflows | Often used to protect a finer stage downstream, where it carries the bulk particulate load at a much lower cost per litre than the fine membrane would |
| 1.0 and 3.0 micron options | Coarse clarification and particulate reduction | Where the objective is protecting downstream equipment or clarity rather than microbial control, and where chemical resistance rather than fineness is the reason PTFE was chosen |
Pore ratings, retention performance, gas flow, liquid flow and pressure-drop values vary by product model. Operating and sterilization limits, integrity-test method and values, and materials of construction are confirmed against the documentation for the specific item quoted rather than assumed from the pore rating or the membrane material.
Start with what the cartridge is actually made of, because it is the first thing an overclaim hides. PTFE membrane resists an unusually wide range of chemistry, and it is tempting to read that as the cartridge being chemically universal. It is not. The support layers, cage, core, end caps and O-rings are generally polypropylene or another polymer, and on most aggressive duties those reach their limit long before the membrane does. Check compatibility and temperature against the full construction — including the seal material, which is frequently the weakest link and the easiest thing to specify wrongly.
Then the failure mode that makes vent filters different from every other cartridge on this site. A hydrophobic vent works because it repels water: gas passes, moisture does not. When the membrane does become wetted — by condensate on a cooling tank, by steam that was not dried off after sterilisation, by liquid carryover or aerosol during a transfer — flow through it drops sharply. The filter has not torn or fouled in the ordinary sense. It has simply stopped passing gas at the rate the tank needs.
That matters because of what a tank vent is for. When liquid is pumped out of a closed vessel, air has to come in at the same volumetric rate or the vessel goes into vacuum, and tanks are far weaker in vacuum than in pressure — a vent that cannot breathe can deform or collapse one. Filling produces the opposite problem. So a vent filter is sized on the fastest liquid transfer rate the vessel will ever see, plus any steam or CIP flow, not on the tank's volume and not on what the pipe size suggests. If the vessel has a rapid-empty pump, that pump sets the vent size.
The practical measures follow from that. Heated or steam-jacketed vent housings exist precisely to keep the membrane dry in condensing service. After steam sterilisation the element should be dried before the vessel is put back into transfer duty rather than immediately afterwards. And note that integrity testing a hydrophobic filter is not the same procedure as testing a wetted hydrophilic one — the methods differ, and both the method and its values must come from that specific product's guide rather than from a general figure.
End-cap, seal material and housing compatibility have to be confirmed before a quotation — and on PTFE duty the seal material deserves as much attention as the membrane.
The standard length range for single and multi-round sanitary and industrial housings.
Positive bayonet retention with a double O-ring seal, where bypass around the element cannot be tolerated.
Double O-ring seal with a flat end, used where the housing is built for it — the codes are not interchangeable.
Compression-sealed between plates, simpler and less expensive where the duty tolerates it.
Self-contained disposable formats with integral housing, common for small-batch, pilot and laboratory gas and liquid duty.
Vent duty elements, sized on the vessel's fastest transfer rate rather than on its volume.
Surface-modified elements for aggressive liquid chemistry, with the full construction checked against the fluid.
Stainless housings with tri-clamp connections, including heated and jacketed vent housings for condensing service.
O-ring and gasket materials selected against the fluid, temperature and sterilization regime — frequently the limiting component.
Sourcing support for test connections, vent and drain arrangements and instrumentation, where required.
PTFE appears in two quite different roles — keeping gas moving where moisture would block it, and surviving chemistry that would attack other membranes.
Hydrophobic vent elements on vessels, sized on transfer rate, with drying after sterilisation treated as part of the procedure rather than an afterthought.
Inlet air and off-gas duty on fermenters, where the filter is exposed to humidity and to repeated sterilisation cycles.
Gas filtration on utility and process lines, with the element and housing rated for the line pressure and any pressure surge on start-up.
Hydrophilic PTFE where the chemistry would attack other membranes, with compatibility confirmed against the whole cartridge construction.
Tank venting and gas filtration on product vessels, and CO₂ filtration on carbonation duty, with material documentation confirmed per product.
Aggressive process chemistry where extractables and cleanliness matter alongside chemical resistance.
Capsule and mini-cartridge formats for development work, chosen so the specification scales to production later.
Eleven inputs turn a PTFE enquiry into a specific recommendation. The first two settle which of the two products you are actually asking for.
Application — gas, vent, liquid, solvent, acid, alkali or process fluid
Hydrophobic or hydrophilic PTFE requirement
Required pore size
Gas flow or liquid flow requirement — and for vent duty, the fastest liquid transfer rate the vessel sees
Cartridge length and the housing configuration it must fit
End-cap style and seal or O-ring material requirement
Operating pressure and temperature
Sterilization or sanitisation requirement, if applicable
Integrity-test method or validation-document requirement, if any
Preferred brand and model, or the approved-vendor list your QA has qualified
Quantity, delivery city and project timeline
For applications requiring critical gas filtration, sterilizing-grade filtration, integrity testing, SIP/autoclave exposure, or validation documentation, ScientificEdge can support product-selection and documentation enquiries based on the manufacturer's product guide, intended use, operating conditions, and buyer QA requirements.
Pore rating, materials of construction throughout, operating limits and — where the manufacturer makes the claim — the basis of any sterilizing-grade designation.
The test method appropriate to that product and form, with its values and conditions. Hydrophobic and hydrophilic elements are not tested the same way.
Compatibility across the whole cartridge — membrane, support, cage, core, end caps and seals — against your chemical at its concentration and temperature.
Extractables data, biological-safety information and Certificates of Analysis or batch records, where the manufacturer issues them for that product.
These documents are not available for every product or every brand, and their scope differs. Chemical compatibility, sterilizing-grade designation, sterilization cycle limits, integrity-test values and extractables data are claims a specific manufacturer makes for a specific product under stated conditions; ScientificEdge coordinates and supplies that documentation where it exists and does not itself validate, test, certify or confer any of it. PTFE's resistance is a property of the membrane and does not extend automatically to the rest of the cartridge, so no cartridge should be treated as universally chemically compatible. Determining suitability for your fluid, gas and process — including any validation a regulated process requires — remains the responsibility of the buyer's QA, validation, process or engineering function.
For vent duty specifically, the sizing question is worth settling in writing at enquiry: the fastest rate liquid enters or leaves the vessel, plus any steam or CIP flow through the vent, and whether the housing is heated. A vent element sized on tank volume rather than transfer rate is the most consequential specification error on this page, because the consequence lands on the vessel rather than on the filter.
ScientificEdge supports sourcing enquiries for PTFE membrane filter cartridges, vent filters, capsule filters, sanitary housings, and related filtration products from suitable reputed brands and suppliers, including Sartorius, Pall, Merck Millipore, Parker domnick hunter, 3M, Cobetter, Graver, and equivalent options, subject to availability, technical compatibility, documentation, and buyer requirement.
Brand names indicate the sourcing enquiries ScientificEdge can support. They do not indicate authorised distribution, official dealership or an exclusive partnership, and no brand logos or compliance badges are displayed. Product and series names are the trademarks of their respective owners and are referenced only because buyers and tender documents specify by them. An equivalent is matched on PTFE form, pore rating and its stated basis, full materials of construction, dimensions, end-cap code and seal material — and on a regulated process or a critical vent, substituting a filter is a change to a qualified arrangement, so equivalence is your QA or engineering function's determination rather than ours.
Most PTFE enquiries arrive naming the material and not the form. Establishing which of the two products is actually wanted is usually the first useful thing that happens.
A supply partner in India for pharmaceutical, biotech, chemical, food and beverage and high-purity process teams.
Help settling the form before the rating, since the two are not interchangeable and look alike in a housing.
Compatibility checked across the whole cartridge construction rather than against the membrane material alone.
Datasheets, validation guides, integrity-test guidance and compatibility information where the manufacturer issues them.
From a single capsule for development through qualified recurring supply for production.
The items around the cartridge, including heated vent housings for condensing service.
Commercial paperwork in the form your procurement requires, with dispatch coordination from Delhi NCR across India.
Fields marked with an asterisk are required. The application and the PTFE form select the product; the flow, housing and sterilization details decide whether it will work in your installation.
A filtration element built from polytetrafluoroethylene membrane, pleated into a standard cartridge envelope with end caps that seat into a matching housing. PTFE is chosen mainly for its chemical-resistance characteristics, which let it handle acids, alkalis and solvents that would attack other membrane materials.
It is supplied in two distinct forms. Hydrophobic PTFE repels water and is used for gas, air and tank-vent duty. Hydrophilic PTFE is surface-modified to wet out and pass liquid, and is used for aqueous, solvent and chemical filtration. The two are not interchangeable, so the form is part of the specification rather than a detail.
Whether the membrane repels water or wets with it. Hydrophobic PTFE will not allow aqueous liquid through without substantial applied pressure, which is exactly the property wanted on a vent: gas passes freely while moisture is held back, so the vent keeps working in humid service.
Hydrophilic PTFE has been surface-modified so liquid wets the membrane and flows through it, while the underlying chemical resistance is retained. That combination is why it is specified for solvent and aggressive-chemistry liquid duty rather than a conventional hydrophilic membrane. Putting either in the other's job fails: a hydrophobic element will not pass your liquid, and a hydrophilic element on a vent blocks as soon as condensate reaches it.
Hydrophobic PTFE, because a vent has to keep passing gas in service that is often humid or condensing, and a wettable membrane would block. The pore rating follows the objective — 0.22 micron where the vent is protecting a vessel from airborne contamination, coarser where the duty is particulate only.
Sizing matters more than on most cartridges. A vent must pass gas at least as fast as liquid leaves the vessel, or the tank goes into vacuum — and tanks are considerably weaker in vacuum than in pressure. Size on the fastest transfer rate the vessel will see plus any steam or CIP flow, not on tank volume. In condensing service a heated or jacketed housing keeps the membrane dry, and the element should be dried after steam sterilisation before the vessel returns to transfer duty.
Hydrophilic PTFE, where the selected product is designed and documented for that fluid. It wets with liquid while retaining the chemical resistance that made PTFE the choice, which is what suits it to solvents, acids, alkalis and reagents.
One caution is worth more than any general recommendation: confirm compatibility against the whole cartridge, not the membrane. Support layers, cage, core, end caps and O-rings are usually polypropylene or another polymer, and on aggressive chemistry those commonly reach their limit before the PTFE does. The seal material in particular is frequently the weakest component and the easiest to specify wrongly. No PTFE cartridge should be treated as universally chemically compatible.
Pore rating, and therefore what each is used for. A 0.45 micron element suits pre-filtration, particulate reduction and clarification. A 0.22 micron element is the rating conventionally associated with sterilizing-filtration and critical gas or vent workflows, where the exact product is validated for that use.
They are frequently used together rather than as alternatives, with a coarser stage carrying the bulk load ahead of the finer one. Note also that flow through a 0.22 element is materially lower than through a 0.45 at the same size, which matters more on gas and vent duty than most buyers expect — check the pressure drop at your intended flow before fixing the size.
They describe how the cartridge seals into the housing. DOE — double open end — is a plain element sealed by compression between plates. Code 7 has a 226 O-ring at one end with a bayonet lock and a fin or spear at the other, positively locating the element so it cannot lift or bypass under flow or a pressure surge. Code 3 uses a 222 O-ring with a flat end.
The codes are not interchangeable, and a Code 7 element will not seat in a Code 3 or DOE housing. Where a defined retention is the point, positive O-ring retention is normally specified, because a compression seal that relaxes leaves a bypass path around the membrane and the rating then means nothing. Confirm the code, and the seal material, against the housing before ordering.
A non-destructive measurement on the installed filter, correlated by the manufacturer to the retention testing performed on that product, confirming the membrane and its seals are intact and that the assembly matches the condition the data applies to.
The method depends on the form. A wetted hydrophilic filter is generally tested by bubble point, diffusion or pressure hold. A hydrophobic filter cannot simply be water-wetted the same way, so hydrophobic elements are commonly tested by a water intrusion method or by an alcohol-based wetting procedure, depending on the product. Because both the method and its limits are product-specific, they must come from that item's own guide rather than from a general figure. An integrity test confirms the filter is intact; it does not by itself establish that your process is validated.
Datasheets, validation guides, integrity-test guidance, chemical compatibility information, extractables or biological-safety documentation and Certificates of Analysis can be coordinated where the relevant manufacturer issues them for the specific product.
They are not available for every product or brand, and their scope differs considerably. On PTFE specifically, the compatibility document is the one worth requesting early, because it is what tells you whether the supports and seals suit your chemistry rather than only the membrane. State what your file needs at enquiry and availability can be confirmed for the specific item before an order is placed.
Sourcing enquiries are supported for reputed brands including Sartorius, Pall, Merck Millipore, Parker domnick hunter, 3M, Cobetter and Graver, along with equivalent options, subject to availability, technical compatibility, documentation and buyer requirement.
This does not indicate authorised distribution, official dealership or an exclusive partnership with any brand. An equivalent is matched on PTFE form, pore rating and its stated basis, full materials of construction, dimensions, end-cap code and seal material. On a regulated process or a critical vent, substituting a filter is a change to a qualified arrangement, so whether an equivalent is acceptable is your QA or engineering function's determination rather than a sourcing question.
Yes. Supply and project coordination run from Delhi NCR across Gujarat, Maharashtra, Tamil Nadu, Telangana, Karnataka, West Bengal and other industrial and pharmaceutical clusters, covering production, pilot, laboratory and institutional requirements.
Cartridges are supplied individually packaged and should be stored sealed, clean and dry within the temperature range the manufacturer states — hydrophobic elements in particular should not be allowed to become wetted in storage. Lead time is confirmed per line item at quotation stage; commonly held ratings move quickly, while specific brands, capsule formats and documented product lines are often imported to order.
The other membrane materials, the pore-size pages, and the housings and stages around a PTFE cartridge.
Connect with ScientificEdge for dependable product selection, transparent quotations, and quick support across laboratory equipment, chemicals, filtration, and ultrapure water workflows.
Why Teams Choose Us
Certified Product Range
Equipment, chemicals, filtration, and water systems from trusted brands.
Technical Buying Support
Practical recommendations based on workflow, compliance, and budget.
Fast PAN-India Dispatch
Coordinated fulfilment with clear updates and responsive communication.