Source hydrophilic PES membrane filter cartridges, 0.22 and 0.45 micron filter options, capsule filters, sanitary housings and process-filtration consumables for pharmaceutical, biotech, food, beverage, high-purity and industrial applications.
ScientificEdge helps laboratories structure product, grade and documentation requirements for instruments, chemicals, filtration systems and consumables before supply is confirmed.
Authentic Supply
Product identity and requested make reviewed against the exact sourcing requirement.
Documentation Support
Clear technical specs, compliance details, and buying clarity.
PAN-India Delivery
Timely fulfilment with responsive coordination across regions.
Partner Confidence
Brand-focused sourcing support
For pharma, research, diagnostics and industrial laboratories that need clear product and documentation discussions.
Featured Brand Portfolio
30 local brand logos
ScientificEdge supports sourcing and supply of suitable PES membrane filter cartridges, sterilizing-grade filter options where product documentation supports the intended use, bioburden-reduction filters, capsule filters, and sanitary filtration accessories based on pore size, fluid compatibility, end-cap configuration, flow rate, integrity-test requirements, sterilization conditions, validation documentation, and buyer specification.
PES membrane filter cartridges are hydrophilic microporous elements built from polyethersulfone membrane, pleated to give a large filtration area in a standard cartridge envelope. They are commonly selected for aqueous and process-liquid duties where a defined pore rating and predictable flow matter more than dirt-holding capacity.
PES is often considered where users want good flow performance at a given pore rating together with low non-specific binding, which matters when the value is in the liquid rather than in what is removed from it — protein solutions, buffers, media and reagents among them. Those are general characteristics of the polymer rather than guarantees: how a specific cartridge behaves with your fluid depends on the product's construction, its wetting agents if any, and the conditions you run it under.
It is worth being precise about what this is not. A pleated membrane cartridge is a surface filter with a defined rating, which is a different device from the nominal depth cartridges used for sediment duty — those hold dirt economically and pass some proportion of particles at their rated size. Where a process needs a defined retention rather than an economical pre-filter, the membrane cartridge is the right device, and the pre-filter that protects it is a separate item rather than a substitute.
Three things vary by manufacturer and product model and cannot be assumed from the material: pore rating and how it is defined, end-cap design and seal material, and operating limits for temperature, differential pressure and sterilization. Where an application calls for sterilizing-grade filtration, that is a product-specific validated claim with its own integrity-test guidance, and final filter selection has to be confirmed by your QA, validation, process or engineering function against the manufacturer's documentation.

Hydrophilic
Wets out with water
No pre-wetting with alcohol needed for aqueous streams, which is a practical reason PES is chosen over hydrophobic membranes for liquid duty.
Defined rating
Surface filtration, not depth
A pleated membrane retains at a defined rating rather than holding dirt economically. That is what makes a protecting pre-filter a separate item, not an optional extra.
Product-specific
Where the claims live
Sterilizing-grade status, extractables data, sterilization limits and integrity-test values belong to a specific product's documentation, not to PES as a material.
Four bands cover the PES range. The right one follows the process requirement and the microbial-control strategy, not the finest rating available.
| Pore size band | Typical use | What to confirm |
|---|---|---|
| 0.1 micron and finer options | Specialised fine-filtration requirements | Used where product documentation and process validation support the intended use. Flow falls and blinding risk rises sharply at these ratings, so a pre-filtration arrangement is normally part of the design rather than an afterthought |
| 0.22 micron options | Suitable sterile-filtration or final-filtration workflows | Specified where the selected product is validated for that application. Sterilizing-grade status, the associated integrity-test values and the conditions they apply under all come from that specific product's validation guide |
| 0.45 micron options | Bioburden reduction, clarification or pre-filtration | A common duty in its own right and also a frequent pre-filter ahead of a 0.22 stage, where it carries the bulk load and extends the life of the finer membrane |
| 0.65 and 1.2 micron options | Clarification and particulate reduction in beverages, process liquids and pre-filtration | Coarser membrane duty where the objective is clarity and protection of downstream stages rather than microbial control |
Pore-size selection must be based on the process requirement, microbial-control strategy, sample or fluid characteristics, and the specific product validation guide. Pore rating and how it is defined, permitted temperature and differential pressure, sterilization conditions and integrity-test values vary by manufacturer and product model, and are confirmed against the documentation for the item quoted.
The phrase is used loosely in procurement and precisely in manufacturing, and the gap between those two uses causes real problems. When a manufacturer designates a filter sterilizing-grade, that designation rests on a bacterial challenge performed under defined conditions — a specified organism at a specified challenge level, a specified fluid, temperature, differential pressure and duration. It is a statement about that product tested that way. It is not a property the cartridge carries into your process.
What that means practically is that the manufacturer's validation establishes the filter is capable, and your own validation establishes that it performs in your fluid, at your temperature and pressure, for your process time, with your bioburden. Different fluids change how organisms behave at the membrane, and process time and pressure change what the filter is being asked to do. This is why regulators expect user validation as well as supplier documentation, and why a filter cannot simply be bought as sterile and installed.
Integrity testing is the bridge between the two. A bubble point, diffusion or pressure-hold test is a non-destructive measurement made on the installed filter, correlated by the manufacturer to the bacterial challenge results for that product. It confirms that this assembly, wetted correctly and installed correctly, matches the condition the retention data was generated on — which is exactly why the test values must come from that product's own documentation rather than from a general figure. It confirms the filter is intact; it does not by itself establish that the process is validated.
Two practical consequences follow, and both are worth building into the specification rather than discovering later. Pre-filtration is a design decision: a 0.22 micron membrane run without a properly sized pre-filter blinds quickly, and the cost of the membranes it consumes exceeds the cost of the pre-filter that would have protected them. And documentation is a lead-time item: validation guides, extractables data and material certification vary by product and by brand, so ask what exists for the specific item at enquiry rather than assuming it is in the box.
End-cap, seal material and housing compatibility have to be confirmed before a quotation — a membrane cartridge that does not seat correctly is not a filter, whatever its rating.
The standard length range for single and multi-round sanitary and industrial housings.
Positive bayonet retention with a double O-ring seal, the usual arrangement where bypass around the element cannot be tolerated.
Double O-ring seal with a flat end, used where the housing is built for it — the codes are not interchangeable.
Compression-sealed between plates, simpler and less expensive where the duty tolerates it.
Self-contained disposable formats with integral housing, common in small-batch, pilot and laboratory workflows.
Pleated construction giving a large membrane area in a standard envelope, in the pore ratings the process requires.
Electropolished stainless housings with tri-clamp connections, drainable and sized to the cartridge count.
O-ring and gasket materials selected against the fluid and the sterilization regime rather than fitted like for like.
The stage that carries the bulk load so the membrane does not — normally a design decision, not an optional accessory.
Sourcing support for test connections, vent and drain arrangements and instrumentation, where required.
PES membrane cartridges are specified across regulated and unregulated duties. What changes is the documentation burden and who signs off the selection.
Process and formulation duties where the filter selection, its validation and its integrity-test regime are all part of the documented process.
Buffers, media and biological solutions where low non-specific binding matters because the value is in the liquid rather than in what is removed.
Reagent and diagnostic fluid preparation at modest volumes, frequently in capsule format for single-batch use.
Point-of-use and loop filtration in high-purity systems, with suitability established against the specific water system rather than assumed.
Clarification and bioburden control on product streams, with food-contact and material documentation confirmed for the specific cartridge.
Clarification of valuable liquids where chemical compatibility with PES and the seal materials is confirmed against the actual fluid.
Particulate and microbial control in high-purity process chemistry, where extractables and cleanliness matter as much as retention.
Development and pilot-scale filtration, typically in capsule or short-length cartridge formats that scale to production later.
Ten inputs turn a filter enquiry into a specific recommendation. The fluid and the filtration objective come first; the rest decide whether the cartridge will fit, seal and survive the process.
Process fluid and its chemical compatibility with PES and the seal materials
Pore size required, and the filtration objective behind it
Required flow rate and the allowable differential pressure
Cartridge length and the housing configuration it must fit
End-cap style and seal or O-ring material requirement
Process temperature, and the sterilization condition if any
Integrity-test method, where the process requires one
Desired pre-filtration arrangement ahead of the membrane
Brand preference, or the approved-vendor list your QA has qualified
Quantity, delivery city, documentation requirement and project timeline
For applications requiring sterilizing-grade filtration, integrity testing, steam sterilization, or regulatory documentation, ScientificEdge can support product-selection and documentation enquiries based on the relevant manufacturer's validation guide, intended use, process conditions, and buyer QA requirements.
The document set that states pore rating, materials, operating limits and — where the manufacturer makes the claim — the basis of any sterilizing-grade designation.
Bubble point, diffusion or pressure-hold values for that specific product, with the wetting fluid and conditions they apply under.
Membrane, support, cage and seal compatibility against your fluid, temperature and cleaning or sterilization chemistry.
Extractables data, biological-safety information and Certificates of Analysis or batch records, where the manufacturer issues them for that product.
These documents are not available for every product or every brand, and their scope differs. Sterilizing-grade designation, extractables data, biological-safety information, sterilization limits and integrity-test values are claims a specific manufacturer makes for a specific product under stated conditions; ScientificEdge coordinates and supplies that documentation where it exists and does not itself validate, test, certify or confer any of it. A manufacturer's validation establishes that a filter is capable under its test conditions — establishing that it performs in your fluid, at your process conditions, remains the responsibility of the buyer's QA, validation, process or engineering function.
Ask early rather than late. Validation guides, extractables packages and material certification vary by product and by brand, and on regulated projects the documentation is often the long pole rather than the cartridge. Stating the requirement at enquiry lets availability be confirmed for the specific item before an order is placed, instead of after a filter has been qualified into a process.
ScientificEdge supports sourcing enquiries for PES membrane filter cartridges, capsule filters, sanitary housings, and related filtration products from suitable reputed brands and suppliers, including Sartorius, Pall, Merck Millipore, Parker domnick hunter, 3M, Cobetter, Graver, and equivalent options, subject to availability, technical compatibility, documentation, and buyer requirement.
Brand names indicate the sourcing enquiries ScientificEdge can support. They do not indicate authorised distribution, official dealership or an exclusive partnership, and no brand logos or compliance badges are displayed. Product and series names are the trademarks of their respective owners and are referenced only because buyers and tender documents specify by them. An equivalent is matched on membrane material, pore rating and its stated basis, dimensions, end-cap code and seal material — and on regulated processes a change of filter is a change to a validated process, so equivalence is your QA function's determination rather than ours.
On regulated work the filter is the easy part. What takes time is confirming it fits, seals, survives the process and comes with the documentation the file needs.
A supply partner in India for pharmaceutical, biotech, diagnostics, food and beverage, and high-purity process teams.
Help matching rating to objective, end-cap code and seal material to the housing, and both to the fluid and sterilization regime.
Coordination of datasheets, validation guides, integrity-test guidance and extractables information where the manufacturer issues them.
From a single capsule for development through qualified recurring supply for production.
The items around the membrane, quoted together so end-cap codes and seal materials match at the outset.
Commercial paperwork in the form your procurement requires, with dispatch coordination from Delhi NCR across India.
Fields marked with an asterisk are required. Fluid and pore size select the filter; the housing, seal and sterilization details decide whether it will work in your installation.
A filtration element built from polyethersulfone membrane, pleated to pack a large membrane area into a standard cartridge envelope and fitted with end caps that seat into a matching housing. PES is hydrophilic, so it wets out with water without needing an alcohol pre-wet, which is one reason it is widely used for aqueous and process-liquid duty.
It is a surface filter with a defined pore rating rather than a depth filter that holds dirt economically. That distinction drives how it is used: a membrane cartridge is specified where a defined retention is the requirement, and it is normally protected by a separate pre-filter that carries the bulk particulate load.
Pore rating, and therefore what each is used for. A 0.45 micron membrane is generally applied to bioburden reduction, clarification and pre-filtration duty. A 0.22 micron membrane is the rating conventionally associated with sterile filtration workflows, where the selected product is validated for that application.
They are frequently used together rather than as alternatives — a 0.45 stage ahead of a 0.22 carries the bulk load and extends the life of the finer membrane considerably. Going straight to 0.22 on an unprotected stream is possible and usually expensive, because the finer membrane blinds on particulate a coarser one would have taken out. Which rating is appropriate follows from the process requirement and the microbial-control strategy, and the sterilizing-grade designation belongs to a specific validated product rather than to the 0.22 rating in general.
Aqueous and process liquids across pharmaceutical, biotech, diagnostics, food and beverage, fine chemical, electronics and laboratory workflows — buffers, media, biological solutions, reagents, process water, product streams and high-value liquids among them. Low non-specific binding makes PES a common choice where the value is in the liquid rather than in what is removed from it.
Suitability for any specific duty depends on chemical compatibility with your fluid at your temperature, the operating and sterilization limits of the particular product, and — on regulated processes — the validation your QA function requires. It should not be assumed from the material alone, and PES should not be specified for Water for Injection production, injectable final filtration, sterile drug manufacture or vaccine processing unless the product documentation and your own validation requirements confirm it.
They describe how the cartridge seals into the housing. DOE — double open end — is a plain element sealed by compression between plates, simple and inexpensive. Code 7 has a 226 O-ring at one end with a bayonet lock and a fin or spear at the other, positively locating the cartridge so it cannot lift or bypass under flow or a pressure surge. Code 3 uses a 222 O-ring with a flat end.
The codes are not interchangeable: a Code 7 cartridge will not seat in a Code 3 or a DOE housing. For membrane filtration where a defined retention is the point, positive O-ring retention is normally specified, because a compression seal that relaxes gives a bypass path around the membrane and the rating then means nothing. Confirm the code against the housing before ordering rather than after.
PES membrane cartridges are widely used in pharmaceutical and biotech processing, but whether a particular filter is suitable for a particular pharmaceutical application is a product-specific and process-specific question rather than a material one.
Where the duty requires sterilizing-grade filtration, the manufacturer's validation establishes what the product is capable of under its stated test conditions, and your own validation establishes that it performs in your fluid, at your process conditions, for your process time. Extractables data, biological-safety information, sterilization limits and integrity-test values all come from that specific product's documentation. ScientificEdge coordinates and supplies that documentation where it exists; the determination of suitability rests with your QA, validation and process functions.
A non-destructive measurement made on the installed, wetted filter to confirm the membrane and its seals are intact and that the assembly matches the condition the manufacturer's retention data was generated on. The common methods are bubble point, diffusion or forward flow, and pressure hold.
Its value comes from correlation: the manufacturer relates the physical test result to the bacterial challenge testing performed on that product, so a passing result on your installed filter indicates it is in the condition that data applies to. Because that correlation is product-specific, the test values and the wetting fluid must come from that product's documentation rather than from a general figure. An integrity test confirms the filter is intact — it does not by itself establish that your process is validated.
Datasheets, validation guides, integrity-test guidance, material compatibility information, extractables or biological-safety documentation and Certificates of Analysis can be coordinated where the relevant manufacturer issues them for the specific product.
They are not available for every product or every brand, and their scope differs considerably between manufacturers and between product lines. State what your file actually needs at enquiry stage and availability can be confirmed for the specific item before an order is placed — which matters, because on regulated projects the documentation is frequently the longer lead time rather than the cartridge.
Sourcing enquiries are supported for reputed brands including Sartorius, Pall, Merck Millipore, Parker domnick hunter, 3M, Cobetter and Graver, along with equivalent options, subject to availability, technical compatibility, documentation and buyer requirement.
This does not indicate authorised distribution, official dealership or an exclusive partnership with any brand. Where an equivalent is offered it is matched on membrane material, pore rating and its stated basis, dimensions, end-cap code and seal material — but note that on a regulated process, substituting a filter is a change to a validated process, so whether an equivalent is acceptable is your QA function's determination rather than a sourcing question.
The process fluid and the filtration objective first, then the pore size, required flow rate and allowable differential pressure, the cartridge length and the housing it must fit, the end-cap style and seal material, the process temperature and any sterilization requirement, and the integrity-test method if the process uses one.
After that: the pre-filtration arrangement, any brand preference or approved-vendor list your QA has qualified, and the quantity, delivery city, documentation requirement and timeline. If this is a replacement for a filter already in use, the existing part number and a photograph of both end caps settle the fit questions immediately.
Yes. Supply and project coordination run from Delhi NCR across Gujarat, Maharashtra, Tamil Nadu, Telangana, Karnataka, West Bengal and other industrial and pharmaceutical clusters, covering production, pilot, laboratory and institutional requirements.
Membrane cartridges are supplied individually packaged and should be stored sealed, clean and within the temperature range the manufacturer states, since packaging integrity is part of what the filter's cleanliness depends on. Lead time is confirmed per line item at quotation stage — commonly stocked ratings and lengths move quickly, while specific brands, capsule formats and documented product lines are often imported to order.
The pore-size pages, the other membrane materials, and the stages that protect a membrane cartridge.
Connect with ScientificEdge for dependable product selection, transparent quotations, and quick support across laboratory equipment, chemicals, filtration, and ultrapure water workflows.
Why Teams Choose Us
Certified Product Range
Equipment, chemicals, filtration, and water systems from trusted brands.
Technical Buying Support
Practical recommendations based on workflow, compliance, and budget.
Fast PAN-India Dispatch
Coordinated fulfilment with clear updates and responsive communication.